● Measurement: Up to 4-channel 3-phase kWh, kVarh, Current, Power, 2~31st Harmonic and etc
● Voltage Rating: 3x220V/380V AC (3P4W)
● Current Rating: 5A, 100A, 400A or 600A AC (with external CTs)
● Frequency: 45~65Hz
● Communication: RS485 (MODBUS-RTU)
● Extra Function: Wireless Communication (4G, WiFi, LoRa and etc); Cable Temperature Measurement; DO/DI Function
● Display: LCD
● Dimension: 87.8*72*97.7mm(L*W*H) — Main Body
● Wiring: 3-phase 4-wire Connection
● Installation: 35mm DIN Rail
● Standard&Certificate: CE; LVD
Multi-circuits Monitoring ● Monitor up to 4×3-phase circuits in total ● Paired CTs with specs of 5A/1.25mA; 100A/20mA; 400A/100mA or 600A/100mA ● External CTs Connectwith ADW210 Main Body thrrough RJ12 Interface |
Expanded Communication Module — AWT100 ● 4G (Global general module) ● WiFi ● LoRaWAN ● LoRa ● NB-IoT |
Cable Temperature&Residual Current Measurement Module — MTL ● Temperature Measurement:-20℃~+100℃ ● Residual Current Measurement:10~3000 mA ● Accuracy:Temperature:± 2℃; Residual Current:1% (Class 1) |
DO/DI Switch Extra Function Module — MK ● 12 channel DI (Digital Input) ● 4 channel DO (Digital Output) |
3-phase 4-wire Wiring of ADW210 monitoring 4 3-phase Circuits
Wiring between ADW210 Main Body and MTL&MK Extra Function Module through RJ45 Interface
Wiring between 1 ADW210 Main Body and 1 AWT100 Communication Module
(Attention: In the connection between 1 ADW210 and 1 AWT100 through RJ45 interface, we don’t need Auxiliary Power Supply for AWT100)
Wiring between more than 1 ADW210 Main Bodies and 1 AWT100 Communication Module
(Attention: In the connection between more than 1 ADW210 and 1 AWT100 through RS485 Serial Ports, we need DC24 or DC12V Auxiliary Power Supply for AWT100)
Installation InstructionTypical Networking ConnectionAuxiliary power | AC/DC 85~265V;consumption≤10VA; | ||
input | Frequency | 45~65Hz; | |
Voltage | AC 3×220V/380V; | ||
Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1s; | |||
Power consumption:≤ 0.5VA; | |||
Current | AC 5A、100A、400A、600A;(External opening transformer) | ||
Overload: 1.2 times of rated value (continuous); 10 times of rated value / 1s; | |||
Power consumption:≤ 0.5VA; | |||
measurement accuracy | Frequency 0.05Hz, voltage and current 0.5 level, active electric energy level 1, reactive electric energy level 2;2-31 times harmonic accuracy: ± 1%; | ||
Features | Pulse output | Output mode: optocoupler pulse with open collector; | |
Communication | RS485、Modbus-RTU;Baud rate 1200~38400; | ||
Switching | input | Dry contact input、Built in power supply; | |
output | Output mode:Relay normally open contact output;contact rating:AC 250V/3A DC 30V/3A; |
Switching Module | Power | RJ45 interface、DC 12V、Power consumption≤1W; |
Communication | RJ45 interface、Modbus-RTU;(Communication with the main Part) | |
Switching input | Dry contact input、Built in power supply; | |
Switching output | Output mode:Relay normally open contact output;contact rating:AC 250V/3A DC 30V/3A; | |
Temperature and leakage module | Power | RJ45 interface、DC 12V、Power consumption≤1W |
Communication | RJ45 interface、Modbus-RTU;(Communication with the main Part) | |
temperature measurement | -20~100℃; | |
Leakage measurement | 10~3000mA; | |
measurement accuracy | temperature ±2℃、Leakage1.0%; |
Safety | Power frequency withstand voltage | >AC 2kV/1min; |
Insulation resistance | >100MΩ; | |
Environment | working temperature:-20℃~+60℃;Storage temperature:-40℃~+70℃;relative humidity:≤95% No condensation;Altitude:≤2500m; | |
electromagnetic compatibility | Better than grade 3; |